POWERLINE
®
UNIVERSAL AC ADAPTER
True RMS Ac/dc Current Digital Clamp Meter Multimeter 2000counts Uni-t Ut210e US. 4.8 out of 5 stars (50). NEW Craftsman Digital Multimeter with 8 Functions & 18 Ranges model 31937511 NR. UEi Test Instruments DL369 Digital Clamp-On Meter. Trending at $99.98. Find many great new & used options and get the best deals for Craftsman 200a AC Clamp-on Adaptor 82379 at the best online prices at eBay! Free shipping for many products! Extech CA200: 200A AC Clamp Adaptor AC Current measurements, no battery required. English User's Manual; French User's Manual; German User's Manual.
Craftsman 200a Ac Clamp-on Adaptor User Manual Guide
OPERATING INSTRUCTIONS
(0900-15, 0900-33)
WARNING: DETERMINING THE PROPER POLARITY AND VOLTAGE SETTINGS, AND
CONFIGURING THIS ADAPTER CORRECTLY ARE THE USER’S RESPONSIBILITIES.
150-2AC Amp-Clamp Adapter Amp-Clamp current probes, used with analog VOMS provide accurate measurements of high AC current found in power systems and related control circuitry. The Amp-Clamp jaws are closed over a conductor in the circuit and the current load is indicated on the connected meter. AC/DC CURRENT CLAMP OPERATOR’S MANUAL INTRODUCTION The AC/DC Current Clamp is an accessory which will allow your multimeter to measure electrical current up to 600 amperes DC/AC, with a frequency response up to 400Hz. When measuring current with this clamp, there is no need to break a circuit or to affect the isolation. APPLICATION PROCEDURE 1.
CAUTION: ELECTRICALLY OPERATED PRODUCT
Not recommended for use by children. As with all electrical products, precautions should be
observed during handling and use to prevent electrical shock. This power unit is intended to
be correctly orientated in a vertical or floor mounted position.
FAILURE TO CONFIGURE THE ADAPTER PROPERLY CAN RESULT IN DAMAGE TO
YOUR CONNECTED DEVICES. NOT FOR USE AS A BATTERY RE-CHARGER
1. Determine which plug tip fits your device by trying each tip in the adapter jack on
your device.
2. Match the polarity symbol on your device to those shown below and attach the plug tip to
the end of the AC adapter cord as indicated. (The polarity symbol for your device may be
either next to the AC adapter jack or in the instruction manual for your device.) If you are
unsure of the correct polarity, DO NOT connect the adapter to your device. For assistance,
please call 1-(800) 637-2867.
3. Set the voltage selection switch on the front of the Universal AC Adapter to the voltage
indicated in the instruction manual for your device. If you do not know the proper voltage,
refer to the battery chart below and set the switch accordingly.
4. Plug the AC adapter cord into your device and then plug the AC adapter into a standard
120 volt outlet. If your device does not operate, unplug the AC adapter immediately and
verify that the voltage selection switch and plug tip polarity have been set properly per
these instructions.
INSTRUCTIONS FOR POLARITY
Look on your product where you plug the adapter in to find the polarity symbol. It will be a plus
and minus sign with a circle between them. The circle will be open on one side, it will look like
the letter “C”. If the “C” is open toward the minus (-) sign, then the polarity needs to be set
TIP-Negative (-). If the “C” is open toward the positive (+) sign, then the polarity needs to be
set TIP-Positive (+).
You will find a plus (+) and minus (-) sign in the
plastic portion of the plug tip directly above the two
pins that connect the tip to the cord. On one side
of the cord where the plug is inserted, is the word
“TIP”. If you need TIP-Positive polarity, insert the
plug with the (+) sign and “TIP” on the same side.
If you need TIP-Negative polarity, insert the plug
with the (-) sign and “TIP” on the same side.
If your product does not have a polarity symbol,
call the manufacturer of your product and ask for
the polarity. Configuring the polarity incorrectly on
the adapter can damage your product.
CAUTION: If the plug polarity and/or voltage
setting are not correct you risk the chance of
damaging your product.
PLUG TIP STORAGE (MODEL 0900-15 ONLY)
The adapter includes a compartment for the convenient storage of the plug tips that are not
in use. Simply slide the storage compartment door open, insert the extra tips and slide the
door back in place.
ONE YEAR LIMITED WARRANTY
Original Power, Inc. warrants this product to the original purchaser to be free of defects in
material and workmanship for one year after the original date of consumer purchase. This
warranty does not include damage caused by accident or misuse. Proof of purchase is
Craftsman 200a Ac Clamp-on Adaptor User Manual Instructions
required to validate your warranty if a claim is made.
IN NO EVENT SHALL ORIGINAL POWER, INC. BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES
Some states do not allow exclusion or limitation of incidental or consequential damages, so
the above exclusion may not apply to you. This warranty gives you specific legal rights, and
you may have other rights that vary from state to state.
If Original Power, Inc., in its sole discretion, determines that the product has become defective
within the warranty period, we will repair or replace it at our option, provided it is returned
postage prepaid to:
Original Power, Inc.
PowerLine
®
Customer Service
3400 Corporate Way, Suite C
Duluth, GA 30096
CALL OUR TOLL-FREE CUSTOMER SERVICE NUMBER FOR
ASSISTANCE BEFORE RETURNING ANY PRODUCT
1-(800) 637-2867
PowerLine
®
is a registered trademark of Original Power, Inc.
4)0
4)0
4)0
4)0
0003
$%6)#%
0003
$%6)#%
Craftsman 200a Ac Clamp-on Adaptor User Manual Diagram
3%4
4()3
0013
0014
0016
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
-AXIMUM
001600100010
0010001900100010 00110015
-AXIMUM
0011001300100010
0010001900100010 00130013
3%4
4()3
0017
0019
00110012
'!44%29
Rotary scale clamp-on model rs-3, Operating instructions, Amprobe
5. With Test Leads Shorted-
Line up pointer with '0' mark on
ohms scale by turning Small
Black Knob on right side of
instrument (Fig 17)
NOTE: If ohmmeter zero adjust
knob does not line pointer up on zero
mark, replace battery with a new one.
Oxidation on base of battery can cause
poor contact. Sand lightly to assure good
contact.
6. To Measure Resistance
between any two points on a
device, simply apply the clip lead
and the ohmmeter attachment
probe tip and read pointer.
HOW TO READ OHMMETER SCALE
The ohmmeter scale is located on the flat plate along the righthand edge of the
window. The zero mark (beginning) is on top of the scale while the infinity mark
“
∞
Craftsman 200a Ac Clamp-on Adaptor User Manual Free
” ends the scale.
OPTIONALEXTENDO LEADS
FOR FASTER AND EASIER VOLTAGE TESTING
EXTENDO TESTLEADS. Cal. No VLK-411R. have
5 inch long insulated probes for a man-sized grip.
One probe clamps between instrument jaws.
Optional alligator clip adaptor (Cat No VRC-320)
converts probe so it can be fastened to test point.
Probe tips are replaceable (Cat No VPT)
Fig 19
FACTORY SERVICE
If the instrument fails to operate, check battery, test leads, etc and replace as
necessary. If the instrument still malfunctions, please call the phone number
listed below:
Tel: 954-499-5400 - 800-327-5060
Outside the U.S.A. the local Amprobe representative will assist you.
RANGE-EXPANDING ACCESSORIES
*Intermittent duty
All of the above are clamp-on type transformers. Models CT-50-1 (six link) and
CT-50-2 (four link) are flexible link construction.
Request Cal. No, AAD38.
Mode
A50-1
CT-50-1
CT-50-2
Ratio
10 to 1
50 to 1
50 to 1
Maximum Range Capability
1,200 amperes*
6,000 amperes*
3,600 amperes*
OTHER ACCESSORIES & REPLACEMENT PARTS
Model
Description
VL-11R..............................................................................Leads
VLK-411R.........................................................................Extendo Leads
VPT...................................................................................Replacement Tips
OHB-3HE .......................................................................Ohmmeter Attachment
8AG-360x023....................................................................Fuse - 600V. 1Amp
A-47L................................................................................Energizer
ADP-46.............................................................................Ground adaptor
912....................................................................................Buttery AAA
VRC-320...........................................................................Alligator Clip
Reg. U.S. Pat. office
Patent nos. 2,663,845
Others Pending
HOW TO INSTALL
FUSE AND BATTERY
Unscrewbaseofohmmeterbattery/fuse attachment
insert fuse (Use Litte/fuse type 8AG - 360x023
1AMPfast blow) and AAAbattery (Cal No 912, not
supplied) into probe end as shown in figure.
Screw base on to probe.
HOW TO USE AS AN OHMMETER
CAUTION:
FOR RS-3 MODELS
.
Make certain no voltage is present in circuit before connecting ohmmeter.
The ohmmeter is fused to help protect it against a misapplication of voltage
but under certain conditions it is still possible to damage the meter and/or
cause personal injury. Use only OHB-3HE ohmmeter attachment with fuse
#8AG-360x023. 1 Amp 600V.
Fig 13
Fuse
Battery
Case
Fuse
Battery
Lid
1. Insert either the Red or Black Voltage
Lead into the Left Voltage Receptacle
at bottom of instrument case (Fig. 14).
2. Insert ohmmeter battery/fuse attachment
into the jack on the right side of the
instrument just below the ohmmeter Zero
Adjust Knob. Seat plug to bottom for
good connection (Fig. 15).
3. Set range Selector so that the 150 volt
red scale appears in window.
4. Ohmmeter Scale Adjustment with test
Craftsman 200a Ac Clamp-on Adaptor User Manual Tool
Leads Open-Pointer should line up with
division marked “
∞
” on OHMS SCALE.
Turn Pointer Zero Adjust Screw if neces-
sary (Fig. 16).
IMPORTANT:
Read 'Precaution for Personal and Instrument Safety'
before using instrument.
Fig 14
Fig 15
Fig 16
Zero
Adjust
Knob
Zero
Adjust
Knob
Fig 17
Fig 18
Fig 19
Zero
Adjust
Knob
NOTE: If you fail to get an ohmmeter indication or the indication is
intermittent, before replacing the battery or fuse, lightly sand the base
of the battery with fine sandpaper. This will remove any oxidation that
could be causing poor or intermittent contact.
CAUTION: Makecertainthatcircuit
is disconnected from line before
takinganyresistance measurements.
|
AMPROBE
®
Miramar, FL
www.amprobe.com
Phone: 954-499-5400
Fax: 954-499-5454
P/N 915741 Rev.B
OPERATING
INSTRUCTIONS
for
AMPROBE
®
Rotary Scale
Clamp-on
Model RS-3
See Precautions for Personal and
Instrument Safety on Page 1
SPECIFICATIONS
AC Voltage Ranges: 0- 150/300/600
AC Amp Ranges: 0-6/15/40/100/300
Ohms : 25 Ohms mid-scale
Frequency Response: 50/60 Hz
Accuracy: Volts and Amps: – ± 3% of Full Scale 50 / 60 Hz
based on sinusoidal waveform
Ohms – ±3% of arc.
Duty: Continuous
Case Breakdown: 3500 Volts
Ohmmeter Protection: Ohm circuit is fuse protected to 600 Volts
PAGE 5
PAGE 4