Craftsman 200a Ac Clamp-on Adaptor User Manual

Advertising

POWERLINE

®

UNIVERSAL AC ADAPTER

True RMS Ac/dc Current Digital Clamp Meter Multimeter 2000counts Uni-t Ut210e US. 4.8 out of 5 stars (50). NEW Craftsman Digital Multimeter with 8 Functions & 18 Ranges model 31937511 NR. UEi Test Instruments DL369 Digital Clamp-On Meter. Trending at $99.98. Find many great new & used options and get the best deals for Craftsman 200a AC Clamp-on Adaptor 82379 at the best online prices at eBay! Free shipping for many products! Extech CA200: 200A AC Clamp Adaptor AC Current measurements, no battery required. English User's Manual; French User's Manual; German User's Manual.

Craftsman 200a Ac Clamp-on Adaptor User Manual Guide

OPERATING INSTRUCTIONS

(0900-15, 0900-33)

WARNING: DETERMINING THE PROPER POLARITY AND VOLTAGE SETTINGS, AND

CONFIGURING THIS ADAPTER CORRECTLY ARE THE USER’S RESPONSIBILITIES.

150-2AC Amp-Clamp Adapter Amp-Clamp current probes, used with analog VOMS provide accurate measurements of high AC current found in power systems and related control circuitry. The Amp-Clamp jaws are closed over a conductor in the circuit and the current load is indicated on the connected meter. AC/DC CURRENT CLAMP OPERATOR’S MANUAL INTRODUCTION The AC/DC Current Clamp is an accessory which will allow your multimeter to measure electrical current up to 600 amperes DC/AC, with a frequency response up to 400Hz. When measuring current with this clamp, there is no need to break a circuit or to affect the isolation. APPLICATION PROCEDURE 1.

CAUTION: ELECTRICALLY OPERATED PRODUCT

Not recommended for use by children. As with all electrical products, precautions should be

observed during handling and use to prevent electrical shock. This power unit is intended to

be correctly orientated in a vertical or floor mounted position.

FAILURE TO CONFIGURE THE ADAPTER PROPERLY CAN RESULT IN DAMAGE TO

YOUR CONNECTED DEVICES. NOT FOR USE AS A BATTERY RE-CHARGER

1. Determine which plug tip fits your device by trying each tip in the adapter jack on

your device.

2. Match the polarity symbol on your device to those shown below and attach the plug tip to

the end of the AC adapter cord as indicated. (The polarity symbol for your device may be

either next to the AC adapter jack or in the instruction manual for your device.) If you are

unsure of the correct polarity, DO NOT connect the adapter to your device. For assistance,

please call 1-(800) 637-2867.

3. Set the voltage selection switch on the front of the Universal AC Adapter to the voltage

indicated in the instruction manual for your device. If you do not know the proper voltage,

refer to the battery chart below and set the switch accordingly.

4. Plug the AC adapter cord into your device and then plug the AC adapter into a standard

120 volt outlet. If your device does not operate, unplug the AC adapter immediately and

verify that the voltage selection switch and plug tip polarity have been set properly per

these instructions.

INSTRUCTIONS FOR POLARITY

Look on your product where you plug the adapter in to find the polarity symbol. It will be a plus

and minus sign with a circle between them. The circle will be open on one side, it will look like

the letter “C”. If the “C” is open toward the minus (-) sign, then the polarity needs to be set

TIP-Negative (-). If the “C” is open toward the positive (+) sign, then the polarity needs to be

set TIP-Positive (+).

You will find a plus (+) and minus (-) sign in the

plastic portion of the plug tip directly above the two

pins that connect the tip to the cord. On one side

of the cord where the plug is inserted, is the word

“TIP”. If you need TIP-Positive polarity, insert the

plug with the (+) sign and “TIP” on the same side.

If you need TIP-Negative polarity, insert the plug

with the (-) sign and “TIP” on the same side.

If your product does not have a polarity symbol,

call the manufacturer of your product and ask for

the polarity. Configuring the polarity incorrectly on

the adapter can damage your product.

CAUTION: If the plug polarity and/or voltage

setting are not correct you risk the chance of

damaging your product.

PLUG TIP STORAGE (MODEL 0900-15 ONLY)

The adapter includes a compartment for the convenient storage of the plug tips that are not

in use. Simply slide the storage compartment door open, insert the extra tips and slide the

door back in place.

ONE YEAR LIMITED WARRANTY

Original Power, Inc. warrants this product to the original purchaser to be free of defects in

material and workmanship for one year after the original date of consumer purchase. This

warranty does not include damage caused by accident or misuse. Proof of purchase is

Craftsman 200a Ac Clamp-on Adaptor User Manual Instructions

required to validate your warranty if a claim is made.

IN NO EVENT SHALL ORIGINAL POWER, INC. BE LIABLE FOR INCIDENTAL OR

CONSEQUENTIAL DAMAGES

Some states do not allow exclusion or limitation of incidental or consequential damages, so

the above exclusion may not apply to you. This warranty gives you specific legal rights, and

you may have other rights that vary from state to state.

If Original Power, Inc., in its sole discretion, determines that the product has become defective

within the warranty period, we will repair or replace it at our option, provided it is returned

postage prepaid to:

Original Power, Inc.

PowerLine

®

Customer Service

3400 Corporate Way, Suite C

Duluth, GA 30096

CALL OUR TOLL-FREE CUSTOMER SERVICE NUMBER FOR

ASSISTANCE BEFORE RETURNING ANY PRODUCT

1-(800) 637-2867

PowerLine

®

is a registered trademark of Original Power, Inc.

4)0

4)0

4)0

4)0

0003

$%6)#%

0003

$%6)#%

Craftsman 200a Ac Clamp-on Adaptor User Manual Diagram

3%4

4()3

0013

0014

š

0016

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

-AXIMUM

001600100010

0010001900100010 00110015

-AXIMUM

0011001300100010

0010001900100010 00130013

3%4

4()3

0017

š

0019

00110012

'!44%29

Advertising
Popular Brands
Popular manuals

Rotary scale clamp-on model rs-3, Operating instructions, Amprobe

Advertising

5. With Test Leads Shorted-

Line up pointer with '0' mark on
ohms scale by turning Small
Black Knob on right side of
instrument (Fig 17)

NOTE: If ohmmeter zero adjust
knob does not line pointer up on zero
mark, replace battery with a new one.
Oxidation on base of battery can cause
poor contact. Sand lightly to assure good
contact.

6. To Measure Resistance

between any two points on a
device, simply apply the clip lead
and the ohmmeter attachment
probe tip and read pointer.

HOW TO READ OHMMETER SCALE
The ohmmeter scale is located on the flat plate along the righthand edge of the
window. The zero mark (beginning) is on top of the scale while the infinity mark

Craftsman 200a Ac Clamp-on Adaptor User Manual Free

” ends the scale.

OPTIONALEXTENDO LEADS
FOR FASTER AND EASIER VOLTAGE TESTING

EXTENDO TESTLEADS. Cal. No VLK-411R. have
5 inch long insulated probes for a man-sized grip.
One probe clamps between instrument jaws.
Optional alligator clip adaptor (Cat No VRC-320)
converts probe so it can be fastened to test point.
Probe tips are replaceable (Cat No VPT)

Fig 19

FACTORY SERVICE

If the instrument fails to operate, check battery, test leads, etc and replace as
necessary. If the instrument still malfunctions, please call the phone number
listed below:
Tel: 954-499-5400 - 800-327-5060
Outside the U.S.A. the local Amprobe representative will assist you.

RANGE-EXPANDING ACCESSORIES

*Intermittent duty
All of the above are clamp-on type transformers. Models CT-50-1 (six link) and
CT-50-2 (four link) are flexible link construction.
Request Cal. No, AAD38.

Mode

A50-1

CT-50-1
CT-50-2

Ratio

10 to 1
50 to 1
50 to 1

Maximum Range Capability

1,200 amperes*
6,000 amperes*
3,600 amperes*

OTHER ACCESSORIES & REPLACEMENT PARTS

Model

Description

VL-11R..............................................................................Leads
VLK-411R.........................................................................Extendo Leads
VPT...................................................................................Replacement Tips
OHB-3HE .......................................................................Ohmmeter Attachment
8AG-360x023....................................................................Fuse - 600V. 1Amp
A-47L................................................................................Energizer
ADP-46.............................................................................Ground adaptor
912....................................................................................Buttery AAA
VRC-320...........................................................................Alligator Clip

Reg. U.S. Pat. office
Patent nos. 2,663,845
Others Pending

HOW TO INSTALL
FUSE AND BATTERY

Unscrewbaseofohmmeterbattery/fuse attachment
insert fuse (Use Litte/fuse type 8AG - 360x023
1AMPfast blow) and AAAbattery (Cal No 912, not
supplied) into probe end as shown in figure.
Screw base on to probe.

HOW TO USE AS AN OHMMETER

CAUTION:

FOR RS-3 MODELS

.

Make certain no voltage is present in circuit before connecting ohmmeter.
The ohmmeter is fused to help protect it against a misapplication of voltage
but under certain conditions it is still possible to damage the meter and/or
cause personal injury. Use only OHB-3HE ohmmeter attachment with fuse
#8AG-360x023. 1 Amp 600V.

Fig 13

Fuse
Battery
Case

Fuse

Battery

Lid

1. Insert either the Red or Black Voltage

Lead into the Left Voltage Receptacle
at bottom of instrument case (Fig. 14).

2. Insert ohmmeter battery/fuse attachment

Craftsman 200a Ac Clamp-on Adaptor User Manual

into the jack on the right side of the
instrument just below the ohmmeter Zero

Adjust Knob. Seat plug to bottom for

good connection (Fig. 15).

3. Set range Selector so that the 150 volt

red scale appears in window.

4. Ohmmeter Scale Adjustment with test

Craftsman 200a Ac Clamp-on Adaptor User Manual Tool

Leads Open-Pointer should line up with
division marked “

” on OHMS SCALE.

Turn Pointer Zero Adjust Screw if neces-
sary (Fig. 16).

IMPORTANT:

Read 'Precaution for Personal and Instrument Safety'

before using instrument.

Fig 14

Fig 15

Fig 16

Zero

Adjust

Knob

Zero

Adjust

Knob

Fig 17

Fig 18

Fig 19

Zero

Adjust

Knob

NOTE: If you fail to get an ohmmeter indication or the indication is
intermittent, before replacing the battery or fuse, lightly sand the base
of the battery with fine sandpaper. This will remove any oxidation that
could be causing poor or intermittent contact.

CAUTION: Makecertainthatcircuit
is disconnected from line before
takinganyresistance measurements.

|

AMPROBE

®

Miramar, FL

www.amprobe.com

Phone: 954-499-5400

Fax: 954-499-5454

P/N 915741 Rev.B

OPERATING

INSTRUCTIONS

for

AMPROBE

®

Rotary Scale

Clamp-on

Model RS-3

See Precautions for Personal and

Instrument Safety on Page 1

SPECIFICATIONS

AC Voltage Ranges: 0- 150/300/600
AC Amp Ranges: 0-6/15/40/100/300
Ohms : 25 Ohms mid-scale
Frequency Response: 50/60 Hz
Accuracy: Volts and Amps: – ± 3% of Full Scale 50 / 60 Hz

based on sinusoidal waveform
Ohms – ±3% of arc.

Duty: Continuous
Case Breakdown: 3500 Volts
Ohmmeter Protection: Ohm circuit is fuse protected to 600 Volts

PAGE 5