Atwood Mobile Products EHM6 Water Heater User Manual. SAFETY INFORMATION. FOR YOUR SAFETY. Fill the heater with water. Open the hot water faucet connected to. The heater until all air is gone. EHM6, EHM11, EHP-10, E20 and EH20. Looking for a owneroperator manual for a Atwood Mobile. I have 8525 iv furnace. Many travel trailers, motor homes and house boats contain water heaters that allow occupants to take advantage of hot water while vacationing. Atwood offers many different models of 6- to 10-gallon water heaters for these purposes. The Atwood GC6AA 10E water heater is a 6-gallon capacity heater that uses both propane gas and electricity to run. Water Heater Wiring Schematics Junction Box on Back of Unit Wiring Schematic G6A-2E, G6A-3E, GHE, GHE Water Heaters (Rear Mount ECO and Battery Thermostat.Atwood Hot Water Heater Wiring Diagram Wiring LibraryATWOOD PILOT 6 GALLON USER MANUAL Pdf Download. Mar 14, 2019 No matter if you lost your original Rheem water heater manual or the previous homeowners didn't leave it behind, here you'll find links to download user manuals in pdf format for the most popular and currently in-use Rheem residential water heaters. Atwood Water Heater Manual. How To Use Atwood RV Water Heater? How To Install? How To Replace Atwood Water Heater. Step By Step User Manual. The correct replacement for your Atwood Water Heater GC6AA-7 is the Atwood RV Water Heater part # AT96117. This water heater has a 6 gallon tank which can produce up to 18 gallons of hot water per hour. It has both gas and electric elements with a manual pilot just like the water heater you have now.
•Installation •Operation •Maintenance
Effective 5/8/2012
LITERATURE NUMBER
MPD 90307
Cold Weather Kit #90290
for On Demand Water Heater Models
OD4501 and OD5001
Cold Weather Kit Installation
1) Installation requires the disconnection of the
water lines, gas line, and electrical connections
in the rear of the unit and removal of the unit
from the RV to a bench.
2) First remove the upper tri-panel by removing
(25) screws, unplugging the pressure switch,
ignition control, relay and blower connection,
and lifting off the case, exposing the interior
components.
3)Next lay out the harness with the ground
eyelet at the grounding point with the existing
ground eyelet, the first and second ceramic at the
locations indicated, the pad behind the
modulation valve, and the thermostat close to the
inlet tube grommet.
Kit Includes:
- Heater Assembly # 90296
o
Ceramic Clips (2)
o
Heater assembly
o
Tie Wraps (2 Long, 4 Short)
- Insulation Tape (36”) (Note: must be cut
into 16”, 14” and 4” pieces)
- Instruction
This kit includes the components necessary to
provide protection of the lower extremities of the
water circuit from freezing.
Protection of the heat exchanger (control of the
burner) is accomplished with a low temperature
thermostat which was provided standard on the
unit. It will provide protection for the heat
exchanger to ambient temperatures as low as 15°
F.
This kit is for adding protection of the lower
extremities i.e. the water tubes and the
modulation valve. It operates automatically
when the internal water temperature drops to
38°F.
Thermostat Replacement: (Part must be
ordered separately, # 90311)This switch is
used to light the burner for a limited ignition
cycle of the burner when temperatures dip to and
below approximately 40° F. It is only effective
when the power (12 vdc) is on and the LP tanks
are not turned off during travel or storage. If
there is continuity (switch closed) when the
ambient temperature is above 60° F, it is faulty
and requires replacement.