Gardner Bender GMT-319 Analog Multimeter, 7 Func, 19 Range, AC/DC Volt, DC Current, Resist, Continuity, Decibl, Batt 1.5/9V, Manual Range, 1/Ea. Part # GMT-319. Testing equipment can be put to good use ensuring that electrical equipment is properly installed and safe to operate. Faulty installations can be More. WHERE TO BUY. Gmt 319 Multimeter Manual L need user manual for GB GMT-19P Need wiring diagram for Gardner Bender GMT319 meter Gardner Bender GB GMT-312 12 Range Pocket Multimeter. Includes safety test leads and instruction manual. Gardner Bender GMT-319 19-Range Analog Multimeter, 1000 V, 500 mA, 10 M ohm, -8 TO 62 db, AA. Manual gb multimeter manual ford chassis manual cisa manual 2015 and 2015 micro tools 1957 cessna 172 manuals gb gdt 294a manual kalmar truck siemens acuson sequoia 512 user manual to asme gdt 190a manual heidelberg xl 105 manual how to use. A multimeter - youtube kobelco gb instruments gmt-12a gmt-12 a manual, instructions massey.

Analog Meter results for gb instruments gmt 312 analog multimeter instruction manual gb gb instruments gmt 319 manual at greenbookee.com - Download free pdf files,ebooks. Analog input. EL3681 as usual in advanced digital multimeters. Automatic or manual range selection, 1.25 A fuse installed + spare fuse, filter deactivatable. Quick instructions on how to use the Gardner Bender GDT-11 digital multimeter, a handheld unit that measures electrical resistance, current and voltage. GB Gardner Bender GMT- 312 12 Range Pocket - Buy GB Gardner Bender GMT-312 12 Range Pocket Multimeter with fast shipping and top-rated customer service. Once you know, you Newegg! Gmt-312 user manual - Gardner Bender product instruction manuals provide complete information on the operation of Gardner. GMT-312 5 Function Analog Multimeter, manual PDF. Read online or download PDF. Page 7 / 26. Gardner Bender GMT-318 6 Function Analog Multimeter User Manual. Gardner Bender Equipment. Manuals Directory ManualsDir.com - online owner manuals library. GMT-318 6-09 manual.qxp 6/8/09 2:03 PM Page 12.

Advertising
Gmt

12

11

voltage is unknown, use the highest range.
If the voltage applied falls within the range
of a lower setting, reset the function/range
switch to the appropriate setting for
greater accuracy.

3) Touch the test leads to the circuit under

test. With AC voltage, the polarity of the
test leads is not a factor.

Use the chart below as a guide to reading
AC voltage measurements:

AC V

Read

and

range

following

multiply

setting

Gb Instruments Gmt-319 User Manual

scale

reading by:

Gb Instruments Gmt-319 Instructions

10

0-10

1

50

0-50

1

250

0-250

1

500

0-50

10

Common AC Voltage Measurements

Instruments

6.1 Wall Receptacles

If the receptacle is controlled by a switch, make
sure the switch is ON. Set the function/range
switch to 250V AC. Touch the test leads to the
“hot” and “neutral” slots of the receptacle (see
fig. 3A). The needle indicator should read 120V
AC on the 0-250 scale. To test for proper
grounding of the receptacle, touch one test lead
to the “hot” (narrow) side of the receptacle, and

the other test lead to the ground slot. The meter
should read 120V AC as before.

Gmt 319 Instruction Manual

7. Resistance/Continuity Measurement

For resistance and continuity testing POWER
MUST BE OFF
:

1) Fully seat the test leads in the input jacks (-)

black lead, (+) red lead.

2) Set the function/range switch to the desired

Gb instruments gmt 319 user manual pdf

position and short the test leads together. Using
the zero ohms adjustment dial, slowly turn the
dial until the needle indicator reads -0- ohms at
the right end of the ohms scale. If the needle will
not zero, replace the internal battery with a new
1.5 volt AA size non-rechargeable battery (see
Battery Replacement).

3) Touch the test leads to the resistance or non-

energized circuit to be measured. Measure the
value of the reading on the green ohms scale
and multiply the reading by 1/10/100. If you’re
making basic continuity tests, the needle
indicator should move all the way to the right
side of the ohms scale if continuity exists.

Note: When switching the unit back and forth
from ohms to other functions, always zero the
needle indicator before taking another reading.
Failure to zero the needle before taking
resistance/continuity measurements will result in
inaccurate readings.

Continuity tests are probably the most frequently
performed electrical troubleshooting procedures
around the home. ALWAYS REMEMBER THAT
CONTINUITY CHECKS ARE TO BE MADE
WITH THE POWER TO THE CIRCUIT

Figure 3

3A

3B

Gmt-319 Instructions